A stage lighting controller for sale in the middle of the market has to justify itself twice over: against a laptop running lighting software, and against a flagship console with a touchscreen and a price to match. Scene memory is what makes the desk feel bigger than its channel count. Each event format can keep its own group of stored looks, so an operator moves from a warm dinner wash to a full dance-floor rig without retyping anything. Moving heads, LED pars, strobes, laser projectors and effect machines can share the single output, provided each fixture is patched into its own address range. For a room that runs more than one kind of night, that organisation matters more than raw channel numbers.
Control Layout & Connections
- 16 output faders, numbered 1–16: the physical side of a lighting console with faders, giving direct level control over the channels you have patched or the groups you have addressed together.
- Four-digit digital display: shows bank, scene and channel values, so you can find your position in a dark booth without a screen.
- 30 banks of 8 scenes: record a look into a slot, then recall a whole bank when the event moves on to its next phase.
- FADE TIME potentiometer: sets the output delay, from a hard cut through to a slow cross-fade between scenes.
- Rear connector panel: the DMX signal output, MIDI ports, a lamp connector for the supplied gooseneck and the DC power input all sit on one edge of this DMX console with MIDI, so cables stay out of the way.
- BLACK OUT key: blanks the stage instantly, by hand or over MIDI.
- Coming from a simpler DMX lighting controller to this stage light console: the jump is the 16 physical faders — every channel in the active bank has its own level under your hand instead of a page in a menu.
- Address the fixtures first — every light needs its own start address set on the fixture itself, because a DMX 512 lighting controller can only send levels to the address it has been patched to.
- Do the arithmetic before you patch — add up the channel footprint of every fixture on the rig and check that the total fits within the patch of this 384 channel DMX controller.
- Choose a bank for the event — a bank groups eight scenes, so give each part of the night its own bank instead of mixing everything into one long list.
- Build and store each look — bring the channels up, set the levels by eye or on the display, and record the result into one of the eight scene slots.
- Set movement if you want it — decide the chase interval and how long each step takes to arrive, then leave those controls alone for the rest of the run.
- Rehearse the changes — step through the stored scenes in running order and adjust anything that reads too bright or too flat once the room is full.
- Run it live on scenes, on a chase, or on sound triggering, and keep your hands free to watch the stage instead of the desk.
Product Advantages & Custom Service
It is a DMX lighting console for sale at the practical end of the market. Everything a working venue reaches for during a show is on the panel; the layers of menus that flagship desks add are not, which is exactly why a new operator can be walked through it in an evening. Set against entry-level controllers, the difference is memory and fader count: a long list of stored looks and 16 channels of physical level control rather than a handful of scenes and a shared master. Build quality is where the money goes instead. The chassis is a desktop console with a matte black control surface, and every unit is run through thorough testing before it is packed, so the DMX controller lighting you receive behaves the same way in week fifty as it did on the first night. Custom work is part of the service, not an exception. Buyers with a fixed installation can ask for parameter adjustments that match the rig they already own, function changes that suit a house style of operation, and packaging or labelling that fits their own brand. Custom sample builds let you test those changes on a real stage light console before committing to a run — tell us the specification you have in mind and we will confirm what can be done and how long it takes.
Fixture Compatibility & Cabling
- Start with the fixtures you already own: any unit that accepts DMX512 and can be set to a start address will respond to this desk — moving heads, LED pars, wash lights, strobes, laser projectors and effect machines, whatever brand is on the housing.
- Match the connector: the output on this console is a 3-pin XLR (XLR-D3F), so fixtures with 5-pin DMX inputs need a 3-pin-to-5-pin adapter cable. Carry two, one for each end of a run, and label them so they come back from every hire.
- Add up the channel footprint before ordering: read the channel count off each fixture's manual and total it against the patch of this 384 channel DMX controller. A rig of 16-channel movers and 4-channel pars lands comfortably inside; a large touring patch does not.
- Keep every address range separate: two fixtures sharing a start address will mirror each other no matter which fader you move, and tracing that on site costs more time than drawing the patch sheet at home.
- Respect the daisy chain: DMX512 is specified for up to 32 units on a single line. Beyond that, or when a second truss position sits at the far end of a long cable run, split the signal with a DMX splitter instead of adding more fixtures to the same chain.
- Count out fixtures with no DMX input: a sound activated lighting controller cannot bring standalone, remote-only or sound-only units under console control, so plan around them rather than discovering it on the first night.
- Leave headroom in the patch: a rig that uses all 384 channels has no room for a rented mover or an extra bar of pars next season, and most mid-size venues grow before they shrink.
- Plan the fader side as well: a lighting console with faders is only as quick as the way its channels are grouped, so keep the sixteen levels under your hand pointed at the things you would genuinely change mid-show.
Application Scenarios
- If you have been looking for a stage lighting controller for sale that can hold several event formats in one week, this is the channel count where that becomes realistic. A venue running club nights, wedding receptions and the occasional conference usually owns one mixed rig — a few moving heads, a row of pars, a strobe, maybe a laser — and needs the desk to remember a different set of looks for each format.
- The three venue families below are where this console earns its keep, and they share one requirement: a DMX controller lighting setup that a staff member can pick up in an evening, because the person behind the desk is rarely a full-time lighting designer.
- Nightclub main floor: a sound activated lighting controller can sit on one chase that follows the DJ's tempo automatically, with beam movers, LED pars and strobes keeping the floor moving while the operator steps away from the desk.
- Bar and music restaurant: three or four stored looks — warm for dinner, saturated for the band, dark for the changeover — recalled by whoever is on shift rather than by a technician.
- KTV and private rooms: give each room group its own bank and staff can change the mood from a single row of scene keys without touching individual fixture addresses.
- Live lounge and small concert room: the eight scenes in a bank cover an opening look, a verse look, a chorus look and a blackout for the encore, with the chase dropped in when the band plays faster than the rehearsal tempo.
- Multi-room venues: one desk travels between a main room and a side bar, because the stored banks and the patched rig are the only two things that have to match.
- A stage lighting controller for sale to the wedding and events market has to do one thing reliably: hit marks that nobody calls out loud. Guests seated, bridal entrance, first dance, dinner service, speeches, cake, last song — each of those is a stored look, and the difference between a polished reception and a frantic one is whether the operator can find it in two seconds. This is where the bank structure of the DMX lighting console does more work than the channel count. Put the ceremony in one bank and the reception in another, and the desk moves from a warm low-level wash to a bright dance-floor look without a single cue being retyped. Soft transitions matter as much as the looks themselves: a slow cross-fade keeps a first dance gentle, while a hard cut gives a corporate reveal its snap. The same approach carries theatrical shows and annual parties, where the scene list follows a running order rather than a clock.
- Exhibition halls and trade stands: a short scene list covers build-up light, public hours and a demo loop, and the stored banks are still there the next morning.
- Campus performances and school halls: volunteers can be shown the scene keys in an afternoon, which matters when the operator changes every semester.
- Outdoor roadshows and product launches: a DMX console with MIDI for this kind of work gets carried in and out of a van every week, and the physical fader row can be re-checked on site in minutes rather than after a boot sequence.
- Small concerts and temporary stages: chases and fade control carry a set when there is no time to program a new look between soundcheck and doors.
- Re-patching between venues: because a DMX 512 lighting controller works on addresses and levels, moving to a new hall means re-addressing the fixtures and re-recording whatever changed, not rebuilding the show from nothing.
Specifications
| Console type | Desktop DMX lighting console with faders |
| Control channels | 384 |
| Protocol | DMX512/1990 |
| Scene memory | 30 banks × 8 programmable scenes |
| Output faders | 16, numbered 1–16 |
| Display | 4-digit digital readout |
| Chase controls | TAP SYNC button, SPEED and FADE TIME potentiometers |
| Audio trigger | Built-in microphone |
| MIDI | MIDI in and thru |
| DMX output | XLR-D3F connector |
| Power input | DC 9 V, 1,000 mA via the supplied adapter |
| Dimensions | 520 × 190 × 78 mm (approx. 20.5 × 7.5 × 3.1 in) |
| Net weight | 3.0 kg |
| Supplied accessories | Gooseneck lamp, power adapter, instruction manual |
| Feature | 384 channel DMX controller (this console) |
| 192-channel DMX 512 lighting controller | |
| Control channels | 384 |
| 192 | |
| Stored looks | 30 banks × 8 programmable scenes, 240 looks in total |
| Multi-scene memory with one-key scene switching | |
| Live control | 16 output faders, four-digit display, blackout key |
| One-key scene recall with real-time parameter adjustment | |
| Triggering | TAP SYNC button, speed and fade potentiometers, built-in microphone, MIDI in and thru |
| Sound-active and automatic modes, emergency mode | |
| Fixture mix | Any DMX512 fixture patched by start address |
| Beam, wash, laser, par and moving-head fixtures in one schedule | |
| Suits | Venues that change format week to week, and one desk covering two rooms |
| A fixed rig playing predictable formats on a regular schedule | |
| Choose it when | The patch total is near 192, you want banks of stored looks rather than a short scene list, or cues arrive from a playback rig over MIDI |
| The rig is small and settled and operators only need a handful of scenes on one key | |
| Headroom | A 200-channel rig leaves 184 channels free for a rented mover or an extra bar of pars |
| Little left once wash lights, pars and two moving heads are patched | |
Placement & Care
Where the desk sits decides how easy the night is. At roughly 52 cm wide and 19 cm deep, the console needs a table or shelf with a little room behind it for the connector panel and the DMX cable. A front-of-house position with a clear sightline to the stage beats a corner of the bar, and the supplied gooseneck lamp plugs into the lamp connector to light the fader row in a dark booth. Run the DMX cable away from mains and amplifier cables where the layout allows, and leave a service loop at both ends so the connectors are not taking the strain.
In daily use, the two things that shorten the life of a DMX controller lighting console are drinks and dust. Keep glasses off the desk, blow dust out of the fader slots with compressed air every few months, and wipe the surface with a dry cloth rather than a solvent. Power comes through the supplied adapter, so use that adapter and a socket that is not shared with power amplifiers — a voltage dip on a shared circuit is far more likely to interrupt a show than anything inside the console. For transport, use a padded case, keep the faders away from the case walls, and coil the DMX cable separately so the connectors do not knock against the control surface.
A venue desk is judged in the two seconds after the power comes back. This stage light console returns to the chase or bank it was running when the supply dropped instead of opening on a blank first page, so the operator confirms the look rather than rebuilding it. The 30 banks of eight scenes are held in memory and survive the cut, and nothing programmed earlier in the week has to be entered again. The gap itself belongs to the fixtures, not to the desk. Once the DMX signal stops, each model follows its own rule — some hold their last levels, some fade out, some drop to a dark default. That is worth testing once in a dry run: unplug the DMX cable, watch what the rig actually does, and write the result on the patch sheet. What the console can guarantee is the state it comes back to. Power practice turns a recovery into a non-event. Keep the DC 9 V, 1,000 mA adapter on a socket that is not shared with power amplifiers, a fridge or kitchen equipment, because a dip on a loaded circuit is far more likely to interrupt a show than anything inside the console. If the venue already has a UPS, put the desk on it — the unit draws very little, so a small UPS carries it for several minutes, long enough to ride out a tripped breaker. Blanking the stage should be done with the blackout key, which works by hand and over MIDI, rather than by pulling the plug; a controlled blackout leaves chases and stored banks exactly where they were.
A DMX console with MIDI on board can also take that blackout from a playback rig when the cue is scripted. When power returns, check three things before the next cue: shutter and strobe states on the fixtures, the chase speed and fade positions on the potentiometers, which can be knocked while someone reaches across the desk, and the display, which should still show the bank you were working in.
Ordering & Delivery
- Payment: T/T, PayPal, Western Union, cash.
- Lead time: 3–10 working days for standard products; 15–30 working days for customized orders.
- Plug type: tell us US, EU, UK or AU when you order — every stage lighting controller for sale is packed with the plug you specify.
- Packing and freight: ask us for the packed weight and carton dimensions so your forwarder can quote accurately; the export carton is sized for one console with its accessories.
- Documentation: CE and RoHS paperwork and the instruction manual file for this DMX 512 lighting controller can be sent with the order when a venue, integrator or tender needs them on file.
- Custom orders: parameter adjustments, function changes, labelling and packaging are quoted per project and carry the longer lead time above.
- Freight terms: tell us whether you need EXW, FOB, CIF, DDP or DAP pricing and we will quote accordingly.
- Spare parts: if a fader or adapter ever needs replacing, ask our sales contact about a spare part rather than retiring the whole console.
Technical Support & Model Matching
Picking the right unit for a room is half the job, so our technical team works with you before you order: tell us the space, ceiling height, throw distance, control setup and the power you have available, and we will say which models fit and which do not. After delivery the same team stays with you — DMX addressing, menu settings, first-cue programming, mounting and step-by-step fault finding. Send photos or a short video and we will tell you what to check first, and quotations come back within 24 hours.
FAQ
How many fixtures will this DMX lighting console actually run?
It depends on the channel footprint of each fixture, which is printed in its manual. A 16-channel moving head uses 16 channels, so 24 of them fill the desk exactly; a simple four-channel par uses four, so the same desk runs 96 of them. Most mixed rigs sit between those two figures, and the practical limit is usually how many faders you want to reach for rather than the channel count itself.
Will it drive moving heads, LED pars, lasers and strobes from different brands together?
Yes, provided each fixture is DMX-controlled and can be given a start address. DMX512/1990 is a shared standard: the console sends levels to addresses, and any fixture listening on those addresses responds, whatever name is on the housing. Mixing brands is normal — just check that the combined channel footprint fits and that every fixture in the chain has the correct address set.
Do I need a laptop or software to run it?
No. Everything happens on the panel: faders for levels, the four-digit display for bank, scene and channel values, and the potentiometers for speed and fade. There is no licence, no dongle and no operating system to update, which is also why this DMX lighting controller suits a venue that does not want a computer in the booth.
What happens if the power is cut in the middle of a show?
When power returns, the desk restarts on the chase or bank it was last running, so you are not left blank while the rest of the room comes back up. Stored scenes stay in memory. The practical precaution is a socket that is not shared with amplifiers or kitchen equipment.
How does the sound-activated mode behave with a live band?
As a sound activated lighting controller, it uses a built-in microphone to pick up the room and advance the chase on the beat, which suits a DJ set or a covers band where the tempo drifts. The microphone triggers the step; the TAP SYNC button or the SPEED potentiometer decides how quickly the next step can arrive. For a fixed-tempo set, a timed chase is steadier than sound triggering.
Can I fire scenes from a MIDI controller or a backing-track computer?
Yes. Scenes and chases can be called over the MIDI interface, and blackout, chase programming and chase movement can all be controlled by MIDI as well as by hand. That makes the desk usable for scripted shows where the cue comes from a playback rig rather than from the operator.
Should I buy this or the 192-channel controller?
Take the 192-channel desk if the rig is fixed, small and unlikely to grow — a handful of pars and two moving heads. Move up to this one when the channel total is close to 192, when you want 30 banks of stored scenes instead of a shorter list, or when the console has to cover more than one room. Running out of channels mid-season is the expensive way to learn the difference.