Red
The default warning read on unlit rural corridors, where a warm signal holds contrast without flooding the scene.
Typical setting: expressway run-in, tunnel approachChoosing the right anti collision laser warning light configuration starts with the road rather than the catalog: match a power tier to the run-in distance you need to cover, then settle color, style and control mode. This selector turns the published figures for the highway laser warning light into a step-by-step choice, so you can define an exact variant before you ask for a quote.

Six common hazard contexts, the tier that usually fits each one, and a direct route to the configurable product page. Read a row across, then carry the power, color and style into your own site notes.
| Road scenario | Power tier | Stated range | Color | Style | Spacing starting point | |
|---|---|---|---|---|---|---|
| Long, monotonous expressway stretch | 10 W | 4000 m | Green | Can rotate | ≈ 1 unit per 3–4 km of run-in | |
| Tunnel approach and portal | 4 W | 2000 m | Red | No rotation | One unit per bore, aimed at the approach lane | |
| Bridge deck | 6 W | 3000 m | Yellow | Can rotate | ≈ 1 unit per 2–3 km, both directions | |
| Mountainous curve | 2 W | 1000 m | Red | Can rotate | 1 unit ahead of the curve entry | |
| Construction or maintenance zone | 500 mW | 200 m | Yellow | No rotation | 1–2 units across the taper | |
| Smart-highway gantry | 6 W | 3000 m | RGB | Can rotate | Gantry-mounted, managed remotely |
Planning starting points only — confirm every row against a site survey, the local road authority's requirements and a conversation with sales before ordering.
Five published tiers set the working scale of the system. Read them as rungs on one ladder, then pick the rung that matches the distance over which you want a driver to register the cue.

| Power tier | Stated range | Where it usually fits |
|---|---|---|
| 500 mW | 200 m | Short advance warning: work zones, low-speed approaches, ramp noses |
| 2 W | 1000 m | Curves, merges and secondary roads with moderate sight distance |
| 4 W | 2000 m | Tunnel approaches and urban expressway run-ins |
| 6 W | 3000 m | Bridges, gantries and mid-length warning runs |
| 10 W | 4000 m | Open expressway and long, monotonous stretches |
The description states a maximum output of up to 6000 mW for green and red lasers, and up to 12000 mW for blue lasers. The power ladder and the color choice are therefore linked, not independent.
Beam angle, divergence and the measurement conditions behind these numbers are not published. Treat the ladder as a comparative scale between tiers rather than a photometric guarantee, and ask sales to confirm the conditions that apply to your site.
Six colors are selectable. The right one depends less on preference and more on what a driver is already looking at when the cue enters their field of view.

The default warning read on unlit rural corridors, where a warm signal holds contrast without flooding the scene.
Typical setting: expressway run-in, tunnel approachReads strongly in mixed ambient light and holds its presence along sodium-lit corridors.
Typical setting: bridges, gantries, long open stretchesThe highest stated output ceiling in the range, at up to 12000 mW, for sites that want a cue standing apart from red and green.
Typical setting: high-glare corridors, coastal bridgesOne housing and several cues: change color by time of night, hazard type or phase of works.
Typical setting: multi-scenario corridors, smart-highway gantriesThe caution color — easy to register in fog, spray and low-contrast daylight.
Typical setting: construction and maintenance zonesA neutral, near-colorless marker for positions where a colored signal would compete with existing signage.
Typical setting: portal and gantry positionsChoose RGB only when the site genuinely needs more than one color on the same hardware. A fixed color is simpler to specify, simpler to stock and simpler to maintain across a long installation.

The first mechanical decision is the style: the product page lists a "Can rotate" version and a "No rotation" version. Both share the same power ladder and color list — the difference is how the cue is aimed and how it is maintained.
Beam angle and laser class are not published on the product page. Request both before you lock an aim or publish an installation drawing.

Three control modes are listed, and they map onto three different levels of site infrastructure. Pick the one your road already supports.
Power draw and cabling expectations are not published. If your gantry or cabinet has a fixed power budget, send the requirement with your RFQ and have sales confirm the figure.

Before you fix a specification, check that the site sits inside the published operating envelope. Where a figure is missing, ask rather than assume.
Laser class documentation is not stated on the product page. Ask for it, and confirm that the mounting height and tilt keep the projected beam on the road surface and clear of the driver's direct sightline in every approved aiming position.
A complete first message shortens the path from selection to a firm quote. Six details do most of the work.

Listed as factory direct manufacturer supply, with wholesale and bulk orders welcome.
OEM and ODM service is stated as supported — bring housing, branding or interface requirements into the first message.
Worldwide shipping is listed, with professional technical support available after delivery.
from the run-in distance you need to cover. the selector pairs 10 W with up to 4000 m, 6 W with up to 3000 m and 4 W with up to 2000 m, then adds colour and style.
10 W, green, rotating, spaced at roughly one unit per 3 to 4 km of run-in. the table treats spacing as a starting point to be refined against the actual approach.
4 W, red, without rotation, one unit per bore aimed at the approach lane. the lower tier is enough because the distance to cover is short.
minus 35 to 40 degrees Celsius. the operating window appears in the specification strip beside the power tiers and the stated range.
they change how the cue is read at distance. the selector keeps colour, style and control mode as separate choices so a green rotating unit and a red static unit are not treated as interchangeable.
the road scenario, the power tier, the stated range, the colour, the style and the spacing, then a site survey against the local road authority requirements and a conversation with sales before ordering.